{"id":1939,"date":"2017-10-12T14:15:34","date_gmt":"2017-10-12T14:15:34","guid":{"rendered":"https:\/\/euron.itirana.online\/?page_id=1939"},"modified":"2017-11-01T14:46:47","modified_gmt":"2017-11-01T13:46:47","slug":"technical-specifications","status":"publish","type":"page","link":"https:\/\/euron-energy.al\/myeuron\/al\/technical-specifications\/","title":{"rendered":"Technical Specifications"},"content":{"rendered":"<p>[vc_row full_width=&#8221;stretch_row&#8221; parallax=&#8221;content-moving-fade&#8221; css=&#8221;.vc_custom_1508288640407{background-color: #efefef !important;}&#8221;][vc_column][vc_row_inner][vc_column_inner]<h4 class=\"sc_title sc_title_divider sc_align_center\" style=\"text-align:center;color:#1e73be;font-weight:600;\" data-animation=\"animated fadeInDown normal\"><span class=\"sc_title_divider_before\" style=\"background-color: #1e73be\"><\/span>Project Technical Specifications<span class=\"sc_title_divider_after\" style=\"background-color: #1e73be\"><\/span><\/h4>[vc_empty_space height=&#8221;12px&#8221;]<h6 class=\"sc_title sc_title_regular sc_align_center\" style=\"text-align:center;color:#1e73be;font-weight:400;\" data-animation=\"animated fadeInDown normal\"><strong>Our Main Contractor: Hydro Energia srl.<\/strong><br \/>\nElectrical System Contractor: STE-Energy srl.<\/h6>[vc_empty_space][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; parallax=&#8221;content-moving-fade&#8221; css=&#8221;.vc_custom_1508753299688{background-color: #efefef !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;]<h5 class=\"sc_title sc_title_regular sc_align_center\" style=\"text-align:center;color:#1e73be;font-weight:600;\" data-animation=\"animated fadeInDown normal\">Bele 1 HPP<\/h5>[vc_empty_space height=&#8221;20px&#8221;][vc_column_text]<\/p>\n<table style=\"width: 95%;\">\n<tbody>\n<tr style=\"background-color: #0077be; color: #ffffff;\">\n<td><strong> Description<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Data<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Unit<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<tbody>\n<tr style=\"background-color: #dddddd;\">\n<td colspan=\"3\">The plant setting foresees 3 generating units, designed in accordance to the data below:<\/td>\n<\/tr>\n<tr>\n<td>Type of Turbines<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">FRANCIS<\/td>\n<\/tr>\n<tr style=\"background-color: #dddddd;\">\n<td>Number of Turbines<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">2<\/td>\n<\/tr>\n<tr>\n<td>Rated Unit Flow rate Q unit<\/td>\n<td style=\"text-align: center;\">4.50<\/td>\n<td style=\"text-align: center;\">m3\/s<\/td>\n<\/tr>\n<tr style=\"background-color: #dddddd;\">\n<td>Rated Net Head<\/td>\n<td style=\"text-align: center;\">64\/68<\/td>\n<td style=\"text-align: center;\">m<\/td>\n<\/tr>\n<tr>\n<td>Hs &#8211; Suction Head of maximum Q unit(*)<\/td>\n<td style=\"text-align: center;\">+1.09<\/td>\n<td style=\"text-align: center;\">m<\/td>\n<\/tr>\n<tr style=\"background-color: #dddddd;\">\n<td>H1 &#8211; Quote Differ, between group axis and penstock axis(*)<\/td>\n<td style=\"text-align: center;\">1081<\/td>\n<td style=\"text-align: center;\">mm<\/td>\n<\/tr>\n<tr>\n<td>Turbine\/Generator nominal speed<\/td>\n<td style=\"text-align: center;\">750<\/td>\n<td style=\"text-align: center;\">rpm<\/td>\n<\/tr>\n<tr style=\"background-color: #dddddd;\">\n<td>Turbine\/Generator runaway speed<\/td>\n<td style=\"text-align: center;\">1944<\/td>\n<td style=\"text-align: center;\">rpm<\/td>\n<\/tr>\n<tr>\n<td>Rated Unit power output<\/td>\n<td style=\"text-align: center;\">2499<\/td>\n<td style=\"text-align: center;\">kw<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;20px&#8221;][\/vc_column][vc_column width=&#8221;1\/2&#8243;]<h5 class=\"sc_title sc_title_regular sc_align_center\" style=\"text-align:center;color:#1e73be;font-weight:600;\" data-animation=\"animated fadeInDown normal\">Topojani 2 HPP<\/h5>[vc_empty_space height=&#8221;20px&#8221;][vc_column_text]<\/p>\n<table style=\"width: 95%;\">\n<tbody>\n<tr style=\"background-color: #0077be; color: #ffffff;\">\n<td><strong> Description<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Data<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Unit<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<tbody>\n<tr style=\"background-color: #dddddd;\">\n<td colspan=\"3\">The plant setting foresees 2 generating units, designed in accordance to the data below:<\/td>\n<\/tr>\n<tr>\n<td>Type of Turbines<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">PELTON<\/td>\n<\/tr>\n<tr style=\"background-color: #dddddd;\">\n<td>Number of Turbines<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">2<\/td>\n<\/tr>\n<tr>\n<td>Rated Unit Flow Rate Q Unit<\/td>\n<td style=\"text-align: center;\">227.81<\/td>\n<td style=\"text-align: center;\">m3\/s<\/td>\n<\/tr>\n<tr style=\"background-color: #dddddd;\">\n<td>Rated Net Head<\/td>\n<td style=\"text-align: center;\">600<\/td>\n<td style=\"text-align: center;\">m<\/td>\n<\/tr>\n<tr>\n<td>Min. Quote of Jets&#8217; axis(**)<\/td>\n<td style=\"text-align: center;\">2902<\/td>\n<td style=\"text-align: center;\">rpm<\/td>\n<\/tr>\n<tr style=\"background-color: #dddddd;\">\n<td>Turbine\/Generator nominal speed<\/td>\n<td style=\"text-align: center;\">1140<\/td>\n<td style=\"text-align: center;\">rpm<\/td>\n<\/tr>\n<tr>\n<td>Turbine\/Generator runaway speed<\/td>\n<td style=\"text-align: center;\">4<\/td>\n<td style=\"text-align: center;\">rpm<\/td>\n<\/tr>\n<tr style=\"background-color: #dddddd;\">\n<td>Rated Unit power output<\/td>\n<td style=\"text-align: center;\">2499<\/td>\n<td style=\"text-align: center;\">kw<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\">\u00a0&#8212;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;10px&#8221;][\/vc_column][vc_column][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row full_width=&#8221;stretch_row&#8221; parallax=&#8221;content-moving-fade&#8221; css=&#8221;.vc_custom_1508288640407{background-color: #efefef !important;}&#8221;][vc_column][vc_row_inner][vc_column_inner][vc_empty_space height=&#8221;12px&#8221;][vc_empty_space][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; parallax=&#8221;content-moving-fade&#8221; css=&#8221;.vc_custom_1508753299688{background-color: #efefef !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text] Description Data Unit The plant setting foresees 3 generating units, designed in accordance to the data [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"translation":{"provider":"WPGlobus","version":"2.12.2","language":"al","enabled_languages":["en","al"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"al":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/euron-energy.al\/myeuron\/al\/wp-json\/wp\/v2\/pages\/1939"}],"collection":[{"href":"https:\/\/euron-energy.al\/myeuron\/al\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/euron-energy.al\/myeuron\/al\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/euron-energy.al\/myeuron\/al\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/euron-energy.al\/myeuron\/al\/wp-json\/wp\/v2\/comments?post=1939"}],"version-history":[{"count":52,"href":"https:\/\/euron-energy.al\/myeuron\/al\/wp-json\/wp\/v2\/pages\/1939\/revisions"}],"predecessor-version":[{"id":2397,"href":"https:\/\/euron-energy.al\/myeuron\/al\/wp-json\/wp\/v2\/pages\/1939\/revisions\/2397"}],"wp:attachment":[{"href":"https:\/\/euron-energy.al\/myeuron\/al\/wp-json\/wp\/v2\/media?parent=1939"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}